Detailed Product Description
SKYLINE: Fire Helmet Fire Resistance Combustion Test Device Standard: GA 44:2004、NFPA 1971-2007: 8.3
Gas Requirements: Propane Gas Dimension: 1,400 Mm (W) X 700 Mm (D) X 1,800 Mm (H)
Weight: 215 KG Electrical Requirements: 220V, 30A

NFPA 1971-2007 Fire Helmet Fire Resistance Combustion Test Device

Product Introduction

Fire helmet fire-resistant combustion test device is developed according to NFPA 1971-2007 test standard. Its test principle is that under the action of thermal radiation, open fire impacts on various components of fire helmet, and then detects its flame-retardant performance.

Performance characteristics

1. The radiation heat source is steel heating pipe. The temperature of heating pipe can be adjusted by using PID temperature control mode, so as to adjust the heat radiation flux. The heat radiation flux can be controlled in the range of 10 kW/m2+1 kW/m2, and the heat radiation flux can be accurately adjusted to 0.1 kW/m2.
2. Imported water-cooled heat flow meter is used to monitor the heat radiation output flux. The measuring range of water-cooled heat flow is 0-50kW/m2.
3. Equipped with self-circulating cooling water device, the surface temperature of water-cooled heat flowmeter can be taken away to achieve protection function.
4. Provide secondary instruments to display the value of heat radiation flux.
5. The burner is a lamp device with a nozzle diameter of 13 mm+3 mm.
6. Provide gas secondary decompression device to provide stable gas pressure;
7. By adjusting the gas flow rate with a rotor flowmeter, the flame temperature can be controlled in the range of 1100 ~1300 C.
8. A K-type thermocouple is equipped to measure the temperature at the tip of the inner flame and provide a secondary instrument to display the flame temperature value.
9. Equipped with time relay, the test time of burning flame of Bunsen lamp can be controlled for 15 seconds.
10. Equipped with time timer, it can record the duration of flame continuation of cap and shell.
11. The radiation source is shielded by pneumatic baffle to avoid the radiation test sample. When the test begins, it opens automatically and closes automatically after the test ends.
12. The radiation heat source radiates directly to the top of the helmet, and the height of the specimen can be adjusted.
13. Equipped with a metal head die that meets the average requirement of GB/T 2428-1998 "Adult Head and Face Size";
14. The metal die is installed in the test cabin and the height can be adjusted manually.
15. Metal die can adjust left and right position by Y axis.
16. The height of the Bunsen lamp device can be adjusted manually according to the height of the helmet when it is placed at 45 degrees.
17. The burner can be moved to the middle part of the high point of the helmet and automatically cut off the combustion gas source after 15 seconds.
18.The combustion area is equipped with closed tempered glass observation door, which can be used for the tester to observe the test process and avoid the interference of external gas flow.

Technical parameters

Standard GA 44:2004,NFPA 1971-2007: 8.3
Application Safety Protection
Size 1,400 mm (W) X 700 mm (D) X 1,800 mm (H)
Weight 215KG
Electrical requirements 220V, 30A
Gas requirements propane gas

Contact Details
Skyline Instruments Co.,LTD

Contact Person: Miss. Kasey

Tel: 86-769-23830463

Fax: 86-769-38818154

Send your inquiry directly to us (0 / 3000)

Other Products